beautypg.com

And 27, Chapter 4 operating instructions, Couplers bpm-e controls 3129 digital display – Bird Technologies 3129 Display User Manual

Page 43: Power on

background image

27

Chapter 4

Operating Instructions

This chapter provides a description of controls and indicators on the BPM-E and
the 3129 Digital Display. Read and become familiar with the following instruc-
tions before operating the unit.

Couplers

The BPM-E does not use elements to sense the RF signal. It uses couplers. The
couplers are fixed in place.

BPM-E Controls

There are two indicators and one control on the BPM-E:

Monitor On LED (green) -

Lights when the unit is powered.

Alarm LED (red) -

Lights when an alarm has been triggered.

Reset Switch -

Press to reset an alarm. If the alarm trigger condition is still

present, the alarm will reactivate.

3129 Digital Display

Power On

After the AC power switch is set to ON, a message will be displayed. Examples of
possible messages are:

‘Digital display ver x.xxx’ Shown at power-up for about 4 seconds.

‘Waiting...’ Shown when no response is received from the BPM-E.

‘Serial Pass Thru...’ Shown when a PC or other remote device is connected
to the Remote Computer Connector on the front panel.

CAUTION

BPM-E signal sensing couplers are fixed in place. Do not attempt to remove or

rotate the couplers. They are calibrated and oriented at the factory and are

not designed to be rotated or removed by the end user. Failure to comply may

result in loss of calibration and accuracy, and in permanent damage to the

unit.

This manual is related to the following products: