Rockwell Automation 20L, LPM20 PowerFlex 700 Active Converter Power Module User Manual
Page 52
![background image](/manuals/581043/52/background.png)
3-16
Programming and Parameters
PowerFlex 700L Active Converter Power Module User Manual
UTILITY
Fa
u
lt
Q
u
eu
e
247
[Fault 3 Code]
Displays the most third recent fault code detected.
Default:
Min/Max:
Units:
Read Only
0/65535
0
248
[Fault 3 Time]
Displays the time stamp for the most third recent fault detected.
Default:
Min/Max:
Units:
Read Only
0.0000/429496.7295
0.0001 Hrs
249
[Fault 4 Code]
Displays the most fourth recent fault code detected.
Default:
Min/Max:
Units:
Read Only
0/65535
0
250
[Fault 4 Time]
Displays the time stamp for the most fourth recent fault detected.
Default:
Min/Max:
Units:
Read Only
0.0000/429496.7295
0.0001 Hrs
260
[Alarm Config]
A set of bits to enable/disable alarm conditions that will initiate a Converter alarm.
•
Bit 0 (Ac Low Volt) sets an alarm when the average AC line voltage is less than the limit in parameter 112 - [Low Vac Lmt].
•
Bit 1 (Ac High Volt) sets an alarm when the average AC line voltage exceeds the limit in parameter 114 - [High Vac Lmt].
•
Bit 2 (Ac Low Freq) sets an alarm when the AC line frequency is less than the limit in parameter 131 - [AC Low Freq Lmt].
•
Bit 3 (Ac High Freq) sets an alarm when the AC line frequency exceeds the limit in parameter 133 - [AC High Freq Lmt].
•
Bit 4 (Ac High dFdt) sets an alarm when the AC line frequency is changing faster than the limit in parameter 135 - [AC Maximum
dF/dt].
•
Bit 5 (I Imbalance) sets an alarm when the phase current imbalance exceeds the limit in parameter 103 - [I Imbalance Lmt].
•
Bit 6 (V Imbalance) sets an alarm when the phase voltage imbalance is greater than the limit in parameter 116 - [V Imbalance
Lmt].
•
Bit 7 (IT Overload) sets an alarm when the Overload counter is greater than 90%.
•
Bit 8 (Ambient Temp) sets an alarm when the ambient temperature exceeds the limit in parameter 120 - [Ambnt Temp Alrm].
•
Bit 9 (Base Temp) sets an alarm when the IGBT base temperature exceeds the limit in parameter 122 - [Base Temp Alrm].
•
Bit 10 (Junction Temp) sets an alarm when the IGBT junction temperature exceeds the limit in parameter 124 - [Junct Temp
Alrm].
•
Bit 11 (Coldplate Temp) sets an alarm when the coldplate temperature is less than the limit in parameter 126 - [CldPlt Temp
Alrm].
•
Bit 12 (PWM SyncLoss) sets an alarm when PWM carrier synchronization is lost.
•
Bit 15 (Start Inhibit) sets an alarm when one or more start inhibits are present.
Fil
e
Gr
oup No.
Parameter Name & Description
Values
Bit
Definition
Sta
rt I
nhibit
PWM Sy
ncLo
ss
Coldplat
e T
emp
Junc
tion
T
emp
Base
T
emp
Ambient
T
emp
IT Ov
er
lo
ad
V I
m
balan
ce
I Imb
al
ance
Ac High dFdt
Ac High F
req
Ac Lo
w
F
req
Ac High V
olt
Ac Lo
w
V
olt
Default
1
x
x
1
0
1
1
1
1
1
1
1
1
1
1
1
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = Disabled
1 = Enabled
x = Reserved