Add the POINT I/O Ethernet Adapter and Digital Output Module to an RSLogix 5000 Project

Add Ladder Logic to Test the 1734-OB4E Module’s Lights

1.

In RSLogix 5000 software’s
controller organizer, expand
Tasks >MainTask>MainProgram.

2.

Double-click MainRoutine.

A blank routine opens.

3.

Add a new rung to the routine.

4.

From the Element Toolbar,
drag and drop an Examine
On element and an Output
Energize element onto the
rung.

5.

Double-click the ? in the
Examine On element.

6.

Type PB for push button.

7.

Press Enter.