beautypg.com

Specifications, Brake specifications environmental specifications – Rockwell Automation MPAR Electric Cylinders  User Manual

Page 42

background image

42 MP-Series Electric Cylinders

Rockwell Automation Publication MPAR-IN001D-EN-P - September 2012

Specifications

Brake Specifications

Environmental Specifications

Electric
Cylinder
Cat. No.

Holding
Force

N (lb)

Coil Current
at 24V DC

A

Brake Response Time

Release

(1)

ms

(1)

Brake release time delay with voltage applied.

Engage (using external
arc-suppression device)

MOV

(2)

ms

(2)

Brake engage time delay with voltage removed and MOV used for arc suppression.

Diode

(3)

ms

(3)

Brake engage time delay with voltage removed and diode used for arc suppression.

MPAR-A/B1xxxB

300 (67)

0.43…0.53

23

9

18

MPAR-A/B1xxxE

350 (79)

MPAR-A/B2xxxC

525 (118)

MPAR-A/B2xxxF

800 (180)

0.46…0.56

58

20

42

MPAR-A/B3xxxE

2364 (531)

0.45…0.55

50

20

110

MPAR-A/B3xxxH

1625 (365)

0.576…0.704

110

25

160

Attribute

Value

Temperature, ambient

0…40 °C (32…104 °F)

Temperature, atorage

-25…60 °C (-13…140 °F)

Relative humidity (noncondensing)

5…95%

Shock

20 g peak, 6 ms duration

Vibration

2.5 g peak @ 30…2000 Hz