Mount the electric cylinder – Rockwell Automation MPAR Electric Cylinders User Manual
Page 10

10 MP-Series Electric Cylinders
Rockwell Automation Publication MPAR-IN001D-EN-P - September 2012
If you are using a coupling piece attachment, catalog number MPAR-NE3612
x, or
trunnion mounting kit, catalog number MPAR-NA1635
xx, see
on
for torque values.
If you are using a rod guide accessory, catalog number MPAR-NE34
xxx or
MPAR-NE150
xxx, adjust the guides of the workload and the electric cylinder so that
they are exactly parallel. This avoids excessive wear on the guide.
Mount the Electric Cylinder
1.
Use stainless steel fasteners to mount your electric cylinder to your application.
2.
Attach power and feedback cables after the electric cylinder is mounted, and use a drip
loop in the cable to keep liquids away from the connectors.
BURN HAZARD: Outer surfaces of the motor can reach high temperatures, 65 °C
(149 °F), during electric cylinder operation. Take precautions to prevent accidental
contact with hot surfaces. Failure to observe these safety precautions can result in
personal injury.
ATTENTION: Consider electric-cylinder surface temperature when selecting
motor-mating connections and cables. Failure to observe these safety precautions can
result in personal injury or damage to equipment.
ATTENTION: Keyed connectors must be properly aligned and hand-tightened the
recommended number of turns.
Improper connector alignment is indicated by the need for excessive force, such as the
need for the use of tools, to fully seat connectors.
Failure to observe these safety precautions could result in damage to the motor and
cable, and their components.