Setting Up DH+ Direct Communications
Using RS-232 to
DH+
Communications
RS-232 to DH+ direct communications use an external converter (1770-KF2).
Important: If you are using an internal interface card, refer to “Using DH+
Direct Communications” on page 5-2.
Hardware
Required Hardware
The hardware required for this type of communications depends on the drive
type. Refer to the following table:
Setting Up the Hardware
To use DriveTools32 with this type of communications, you must:
•
Ensure that the drive and adapter are properly installed and powered.
•
Ensure that cables are securely connected and protected from damage.
Configuring RSLinx
For RS-232 to DH+ communications, you must configure RSLinx for RS-232
serial communications. Refer to the “Configuring RSLinx” section in Chapter 3,
Setting Up RS-232 Point-to-Point Serial Communications, for instructions on
configuring RSLinx.
Drive
Required Drive Hardware
Required Computer Hardware
1336
FORCE
PLC Communications Adapter Board
(1336-GT1EN)
RS-232 port and 1770-KF2
1395
Multi-Communications Adapter Board
(1395-KP51)
RS-232 port and 1770-KF2
A-B/
Stromberg
3500-TBX card
(147096 or 157676)
RS-232 port and 1770-KF2