Using drivetools32 with a 1395 drive – Rockwell Automation 9303 DRIVE TOOLS 32 VER 2.50 GETTING STARTED User Manual
Page 21
![background image](/manuals/580159/21/background.png)
Overview
1-7
Using DriveTools32 with a 1395 Drive
With the 1395 drive, you have the following options:
Communications
Required Drive Hardware
Required Computer Hardware
Refer To:
RS-232 Point-to-Point Serial
1300-ITSSC
RS-232 port
RS-232 Serial to DH+ Direct
Multi-Communications Adapter Board
(1395-KP51)
RS-232 port and 1770-KF2
DH+ Direct
Multi-Communications Adapter Board
(1935-KP51)
1784-KT, -KTX, -KTXD, or -PCMK
DH+ to RIO Block Transfer
Pass Thru
Node Adapter (1395-KP50) or
Multi-Communications Adapter (1395-KP51)
1784-KT, -KTX, -KTXD, or -PCMK
RS-232 to ControlNet Direct
ControlNet Adapter Board (1395-KP54EN),
ControlNet Repeater Adapter (1786-RPA),
and ControlNet Fiber Module (1786-RPFM)
1770-KFC & RS-232 port
ControlNet Direct
ControlNet Adapter Board (1395-KP54EN),
ControlNet Repeater Adapter (1786-RPA),
and ControlNet Fiber Module (1786-RPFM)
1784-KTC, -KTCX, or -PCC
RS-232 to ControlNet to
RIO Block Transfer Pass
Thru (PLC)
Node Adapter (1395-KP50) or
Multi-Communications Adapter (1395-KP51)
1770-KFC & RS-232 port
ControlNet to RIO Block
Transfer Pass Thru (PLC)
Node Adapter (1395-KP50) or
Multi-Communications Adapter (1395-KP51)
1784-KTC, -KTCX, or -PCC
Ethernet to RIO Block
Transfer Pass Thru
Node Adapter (1395-KP50) or
Multi-Communications Adapter (1395-KP51)
Ethernet Interface Running TCP/IP
RSLinx Gateway Server:
Ethernet to DH+ Direct
Multi-Communications Adapter (1395-KP51)
Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KT, -KTX, -KTXD, or -PCMK
RSLinx Gateway Server:
Ethernet to DH+ to RIO
Block Transfer Pass Thru
Node Adapter (1395-KP50) or
Multi-Communications Adapter (1395-KP51)
Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KT, -KTX, -KTXD, or -PCMK
RSLinx Gateway Server:
Ethernet to ControlNet
Direct
ControlNet Adapter Board (1395-KP54EN),
ControlNet Repeater Adapter (1786-RPA),
and ControlNet Fiber Module (1786-RPFM)
Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KTC, -KTCX, or -PCC
ControlLogix
Equipment depends on network to which the
drive is connected.
Equipment depends on network to which the
computer is connected.
ControlLogix to RIO Block
Transfer Pass Thru
Multi-Communications Adapter (1395-KP51)
Equipment depends on network to which the
computer is connected.