Using drivetools32 with a 1336 force drive – Rockwell Automation 9303 DRIVE TOOLS 32 VER 2.50 GETTING STARTED User Manual
Page 20

1-6
Overview
Using DriveTools32 with a 1336 FORCE Drive
The 1336 FORCE drives are SCANport-compatible products and offer all of the
options available to SCANport-compatible products (refer to page 1-5). In
addition, 1336 FORCE drives offer the following options:
Communications
Required Drive Hardware
Required Computer Hardware
Refer To:
RS-232 Serial to DH+
Direct
PLC Communications Adapter Board
(1336T-GT1EN)
RS-232 port and 1770-KF2
DH+ Direct
PLC Communications Adapter Board
(1336T-GT1EN)
1784-KT, -KTX, -KTXD, or -PCMK
DH+ to RIO Block Transfer
Pass Thru
PLC Communications Adapter Board
(1336T-GT1EN)
1784-KT, -KTX, -KTXD, or -PCMK
RS-232 to ControlNet
Direct
ControlNet Adapter Board (1336T-GT3EN),
ControlNet Repeater Adapter (1786-RPA), and
ControlNet Fiber Module (1786-RPFM)
1770-KFC & RS-232 port
ControlNet Direct
ControlNet Adapter Board (1336T-GT3EN),
ControlNet Repeater Adapter (1786-RPA), and
ControlNet Fiber Module (1786-RPFM)
1784-KTC, -KTCX, or -PCC
RS-232 to ControlNet to
RIO Block Transfer Pass
Thru (PLC)
PLC Communications Adapter Board
(1336T-GT1EN)
1770-KFC & RS-232 port
ControlNet to RIO Block
Transfer Pass Thru (PLC)
PLC Communications Adapter Board
(1336T-GT1EN)
1784-KTC, -KTCX, or -PCC
Ethernet to RIO Block
Transfer Pass Thru
PLC Communications Adapter Board
(1336T-GT1EN)
Ethernet Interface Running TCP/IP
RSLinx Gateway Server:
Ethernet to DH+ Direct
PLC Communications Adapter Board
(1336T-GT1EN)
Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/
IP and 1784-KT, -KTX, -KTXD, or -PCMK
RSLinx Gateway Server:
Ethernet to DH+ to RIO
Block Transfer Pass Thru
PLC Communications Adapter Board
(1336T-GT1EN)
Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/
IP and 1784-KT, -KTX, -KTXD, or -PCMK
RSLinx Gateway Server:
Ethernet to ControlNet
Direct
ControlNet Adapter Board (1336T-GT3EN),
ControlNet Repeater Adapter (1786-RPA), and
ControlNet Fiber Module (1786-RPFM)
Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/
IP and 1784-KTC, -KTCX, or -PCC
ControlLogix
Equipment depends on network to which the drive
is connected.
Equipment depends on network to which
the computer is connected.
ControlLogix to RIO Block
Transfer Pass Thru
PLC Communications Adapter Board
(1336T-GT1EN)
Equipment depends on network to which
the computer is connected.