Chapter 2

Organize tags

The minimum memory allocation for a tag is four bytes. When you create a tag

that stores data that requires less than four bytes, the controller allocates four

bytes, but the data only fills the part it needs.

Data Type

Bits

31

16

15

8

7

1

0

BOOL

Not used

0 or 1

SINT

Not used

-128…+127

INT

Not used

-32,768…+32,767

DINT

-2,147,483,648…+2,147,483,647

REAL

-3.40282347E

38

…-1.17549435E

-38

(negative values)

0

-1.17549435E

-38

-…3.40282347E

38

(positive values)

The COUNTER and TIMER data types are examples of commonly used

structures.

Item

Description
To expand a structure and display its members, click the + sign.

To collapse a structure and hide its members, click the – sign.

Members of running_seconds.

COUNTER Structure.

TIMER Structure.

Data Type Members.

To copy data to a structure, use the COP instruction.

Refer to the

Logix5000 Controllers General Instructions Reference Manual

,

publication

1756-RM003

.

24

Rockwell Automation Publication 1756-PM004E-EN-P - October 2014