Rockwell Automation 1783-EMS08T Stratix 6000 Ethernet Managed Switch User Manual User Manual
Page 19

Rockwell Automation Publication 1783-UM001D-EN-P - January 2013
19
Basic Configuration
Chapter 1
Table 3 - Miscellaneous Switch Settings
Setting
Description
Box Name
Lets you give your 1783-EMS switch a name that describes its location or connected devices. This feature is useful when multiple 1783-EMS
switches are installed. The switch reports this name on the home page. To change this setting, complete this procedure.
1. Click Basic Configuration.
2. Click Miscellaneous.
3. Type the new name in the text box and click Apply Changes.
The new name does not show in the home page until you click Refresh on the browser.
Minutes of User Inactivity
Lets you change the length of time the management interface (HTTP session) remains open while inactive. Choose from 0…99 min. Select
0 = Feature Disabled for the interface to remain open until it is closed. The default is 3 min.
Seconds Between Refresh
Controls the refresh rate of the management interface.
• Valid values are 0…99 seconds
• 0 = Feature disabled for no refresh
• Default value is 5 seconds
Contact Info, Contact Email
Use to identify the responsible service personnel.