Document update du–4 – Rockwell Automation 160 SER A FRN 1.XX-4.XX User Manual
Page 7
Document Update
DU–4
Figure 2.6 - TB3 Three Wire Control (Setting 0)
Applies to Analog Signal Follower and Preset Speed Models
8
7
6
5
4
3
2
1
9
10
Reverse
Start
Common
Stop
Signal
Specification
Contact closure input required
to operate controller
À
Common
Â
Control closure input
À
Terminal
TB3
11
Shielded Wire
Contact closure input
À
Figure 2.7b - TB3 Two Wire Run Forward"
Ã
ConĆ
trol (Setting 1)
Applies to Analog Signal Follower Models Only
8
7
6
5
4
3
2
1
9
10
Contact closure input
À
Terminal
TB3
Run Forward
Á
Common
Stop
Contact closure input required
to operate controller
À
Common
Â
Signal
Specification
Shielded Wire
11
Figure 2.7d - TB3 Two Wire Run Forward/Run
Reverse"Ä Control (Setting 1)
Applies to Analog Signal Follower Models Only
8
7
6
5
4
3
2
1
9
10
TB3
Á
Type IN4004
Terminal
Signal
Specification
Run Forward
Contact closure input
À
Contact closure input
À
Common
Stop
Contact Closure input required
to operate controller
À
Common
Â
Run Reverse
Shielded Wire
11
Explanation of Symbols
=
N.C. Momentary
=
N.O. Momentary
=
N.O. Maintained
=
N.C. Maintained
Figure 2.7a - TB3 Two Wire Run Forward/Run
Reverse" Control (Setting 1)
Applies to Preset Speed Models Only
8
7
6
5
4
3
2
1
9
10
TB3
11
Á
Terminal
Signal
Specification
Run Forward
Contact closure input
À
Contact Closure input
À
Common
Stop
Contact closure input required
to operate controller
À
Common
Â
Run Reverse
Shielded Wire
Figure 2.7c - TB3 Two Wire Run Forward/Run
Reverse"
Ä
Control (Setting 1)
Applies to Analog Signal Follower Models Only
Á
8
7
6
5
4
3
2
1
9
10
TB3
11
Terminal Signal
Specification
Run Forward
Contact closure input
À
Contact closure input
À
Common
Stop
Contact closure input required
to operate controller
À
Common
Â
Run Reverse
Shielded Wire
Figure 2.8 - TB3 Momentary Run Forward/Run
Reverse" Control (Setting 3)
Applies to Preset Speed Models Only
Á
8
7
6
5
4
3
2
1
9
10
TB3 Terminal
Signal
Specification
Run Forward
Contact closure input
À
Contact closure input
À
Common
Stop
Contact closure input required
to operate controller
À
Common
Â
Run Reverse
Shielded Wire
11
À Internal 12V supply.
Á If both Run Forward and Run Reverse inputs are closed at the same time an undetermined state could occur.
 Do not exceed control wiring length of 15 meters (50 feet). Control signal cable length is highly dependent on electrical
environment and installation practices. To improve noise immunity the control terminal block common must be connected to
earth ground. Consult factory for longer control signal cable length applications.
à Upon power up of the controller, FAULT 22 (stop input not present) will occur. To clear the fault, you must cycle the input to the Run Forward
command.
Ä Upon power up of the controller, FAULT 22 (stop input not present) will occur. To clear the fault, you must cycle the input to the Run Forward or
Run Reverse commands.