Program groups, 37 [maximum voltage, 38 [boost select – Rockwell Automation 160 SER A FRN 1.XX-4.XX User Manual
Page 31: 39 [skip frequency, 40 [skip frequency band, P# parameter description

Chapter 5 - Parameters and Programming
5–5
Program Groups
P#
Parameter Description
Min/Max
Range
Units
Factory
Default
37
[Maximum Voltage]
Sets the highest voltage that the controller will
output.
P37 - [Maximum Voltage] must be greater than or equal to P36 - [Base Voltage].
20 to 460 for
460V units and
20 to 230 for
230V units
1 Volt
460 Volts for
460V units
and 230 for
230V units
38
[Boost Select]
Sets the boost voltage and redefines the Volts per Hz curve.
[Base Frequency], %
[Base V
oltage], % 50
100
1/2
Base
Volts
50
100
1/2
Base
Freq.
9
10
1
1
12
0
1
8
y
b
See Settings 1
through 8 below
Setting Boost Voltage % of [Base Voltage]
1
2.5
2
5.0
3
7.5
4
10.0
5
12.5
6
15.0
7
17.5
8
20.0
0
0
SettingFan/Pump Curves
А
А Break Point Voltages in %
of [Base Voltage].
9
45.0
10
40.0
11
35.0
12
30.0
0 to 12
Numeric
Value
4
39
[Skip Frequency]
Works in conjunction with P40 - [Skip Frequency
Band] creating a range of frequencies at which the controller will not operate
continuously.
'
b
y
Two times
P40-[Skip Freq Band
Setting
'
Skip
Frequency
Setting
Frequency
Time
Controller Output
Frequency
a
Command
Frequency
0 to 240
1 Hz
240 Hz
40
[Skip Frequency Band]
Determines the band around the P39 - [Skip
Frequency] parameter. The actual band width will be 2 times [Skip Frequency
Band] - 1/2 the band above and 1/2 the band below. A value of zero will disable
the skip frequency.
0 to 30
1 Hz
0 Hz