Original instructions, 4 data sheet – Rockwell Automation 442L SafeZone Singlezone & Multizone Safety Laser Scanner User Manual
Page 47

SafeZone™ Safety Laser Scanner User Manual
10000073050, July 2011 45
R
Original instructions
11.4 Data sheet
Minimum
Typical
Maximum
General Data
Laser protection class
Laser class I (21 CFR 1040, 10 and 1040.11, DIN EN 60825:2001)
Enclosure rating
IP65 (EN 60529)
Protection class according to DIN VDE 0106, DIN EN 50178
II
Type according to IEC/EN 61496, part 3
3
Functional safety programmable electronic system (IEC/EN 61508)
SIL 2
PFD - probability of failure on demand (minimum requirement = 1E-2)
4.46E-3
Operating temperature range
-10°C
+50°C
Storage temperature range
-25°C
+70°C max.
24 h
Humidity (taking into account the operating temperature range)
IEC/EN 61496-1, section 5.1.2 and 5.4.2, as well as IEC 61496-3, section 5.4.2
Vibration
IEC/EN 61496-1, section 5.1.2 and 5.4.4.1, as well as
IEC 61496-3, section 5.4.4.2
Frequency range
10 Hz
150 Hz
Amplitude
0.35 mm or 5 g
Shock resistance
Single shock
15 g, 11 ms according to EN 60068-2-27
10 g, 16 ms according to IEC/EN 61496-1, section 5.1.2 and 5.4.4.2, as well as IEC 61
496-3, section 5.4.4.2
Sender
Pulsed laser diode
Wavelength
880 nm
905 nm
935 nm
Divergence of the collimated beam
2.5 mrad
Pulse duration
3.1 ns
Average output power
562 μW
Size of light spot at the front screen
12 mm
Size of light spot at 4.0 m scanning range
23 mm
Size of light spot at 5.0 m scanning range
27 mm
Housing
Material
Aluminium die-cast
Color
RAL 1021
Front screen
Material
Polycarbonate
Surface finish
Outside with scratch-resistant coating
System connector
ESD protected
Dimensions SafeZone multizone safety laser scanner)
Height
185 mm
Width
155 mm
Depth
160 mm
Total weight
3.3 kg