beautypg.com

Precharge scr module - dc input only – Rockwell Automation 20B PowerFlex 700 Drive - Frame 7 Components Replacement User Manual

Page 57

background image

Rockwell Automation Publication 20B-IN017B-EN-P - September 2011

57

Component Replacement Procedures Chapter 3

Install Components

1. Replace washers on Snubber Board Bus Bar studs.

2. Replace insulation over washers.

3. Place new Snubber Board over insulation.

4. Install M6 nuts on studs with star washer side facing Snubber Board. Do

not tighten yet.

5. Center insulation around washers so it is not pinched between the Bus

Bar and any washer or nut.

6. Torque M6 nuts to 2.9 N•m (26 lb•in)

7. Replace push-on wire.

8. Reassemble remaining components in reverse order.

9. Replace all safety shields and enclosure covers before applying power to

the drive.

Precharge SCR Module - DC
Input Only

Refer to the figures in

Component Diagrams and Torque Specs on page 13

and

Figure 5 - on page 56

for these instructions.

Remove Components

1. Read and follow the

Safety Precautions on page 9

and

Important Initial

Steps on page 11

.

2. Locate the Precharge SCR module to be replaced.

3. Perform

Remove Main Control Panel Assembly on page 21

.

4. Perform

Remove Stacking Panel on page 22

.

5. Label and remove power cables (DC+ and DC–) and all connected

wires from the SCR module.

6. Remove the entire Snubber Board Bus Bar assembly, including its lead

wires, and carefully set assembly aside.

7. Remove the SCR module and discard.