21

Operation Method

Auto Start Operation

3

Set temperature and start wait period/time

AUTO START

FIXED TEMP

AUTO STOP

PROGRAM

STANDBY

END

HEATER

FAN

FUNCTION

PROGRAM

MENU

ENTER

CANCEL

SUBMENU

POWER

TROUBLE

Set TEMP

0℃

Auto-start OPR

DOOR

AUTO START

FIXED TEMP

AUTO STOP

PROGRAM

STANDBY

END

HEATER

FAN

FUNCTION

PROGRAM

MENU

ENTER

CANCEL

SUBMENU

POWER

TROUBLE

Set TEMP

100℃

Auto-start OPR

DOOR

The setting temperature input screen is
displayed. The Sub Display indicates "Set
TEMP" and the numeric character that indicates
temperature blinks.

Set the temperature using the "▲▼".

Press the ENTER key to decide the temperature.

The operation start wait period/time input screen

is displayed after the setting temperature is
decided.
Display the operation start wait period/time using
the "▲▼".
Input the operation start wait period when the
setting of timer mode shows "Time". Input the
operation start time when it shows "Clock".

Wait ST

30min

Auto-start OPR

Start Time

13:00

Auto-start OPR

(Operation start wait

period edition screen)

(Operation start time

edition screen)

• The display style of operation start wait period

varies depending on the range of time to be
displayed.

Time Range

Indication

0minute to 59minutes

0min to 59min

1hour to

99hours59minutes

1h00m to 99h59m

• The input range of operation start time is always

from 0:00 to 23:59.

4

Start operation

AUTO START

FIXED TEMP

AUTO STOP

PROGRAM

STANDBY

END

HEATER

FAN

FUNCTION

PROGRAM

MENU

ENTER

CANCEL

SUBMENU

POWER

TROUBLE

Set TEMP

100℃

Start in

30min

DOOR

AUTO START

FIXED TEMP

AUTO STOP

PROGRAM

STANDBY

END

HEATER

FAN

FUNCTION

PROGRAM

MENU

ENTER

CANCEL

SUBMENU

POWER

TROUBLE

Set TEMP

100℃↑

2002/01/01 12:30

DOOR

Press the ENTER key to decide the operation

start wait period/time. The unit enters to auto
start operation wait state. The blinking AUTO
START lamp lights on and the STANDBY lamp
blinks instead in this state. The fan rotates or
stops according to the setting of "Fan (standby)".
The Sub Display displays the setting temperature
and residual time to operation start.

The operation starts when the residual time

counts zero. The STANDBY lamp lights off and
the Sub Display displays the same subject as in
the fixed temperature operation after the
operation starts.

Press the POWER key to cancel or quit the wait

state.