Aeris installation and service manual – STEMCO Aeris User Manual
Page 41
Aeris Installation and Service Manual
Page 41 of 42
• If the pressure is correct, replace metal cap and close the lid.
• If the pressure is above or below the desired setting, adjust the pressure using the adjustment
knob. See Figure 36.
• If the pressure is “low” pull up on the regulator’s knob to unlock. Turn the knob clockwise
to increase the pressure. Allow the pressure to stabilize then check the pressure 2-3 times
to verify correct pressure. If the pressure is correct, push the knob back down to lock in
place and replace the metal cap.
• If the pressure is “high” turn the knob counter-clockwise to decrease the pressure. Allow
the system to stabilize and check the pressure 2-3 times to verify correct pressure.
Continue to decrease or increase the regulator until the desired pressure is achieved.
Figure 37
Troubleshooting
AERIS Control Box installation debugging techniques
With the entire system connected apply power. Does the red light on the circuit board blink at
power up?
If no then check power connections +12 and Ground continuity to the circuit board and 7 pin
connector.
After power up works successfully take off the power lead and the light lead and connect them
together the light should light up.
If no then the connection to the light yellow line is not connected or the light is not grounded.