Step 5 – SDC 350 NARROW LIINE EMLOCK User Manual
Page 6
5. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the
door. Tap with a soft hammer to ensure proper alignment and engagement.
CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head
screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the
threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing
STEP 5
6. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock.
LED Status Indicator:
RED – Energized and Unsecure GREEN – Energized and Secure
P:\INSTALLATION INST\Electromagnetic Locks\INST-352.vsd REV -
02-12 Page 3
To maintain surface plating from corrosion:
Do not touch the lock face with your hands.
Clean lock face with Scotch-Brite pad by 3M (do not use
sandpaper).
Apply a thin film of rust inhibitor (LPS-3) on lock face.
Repeat application on armature plate.
COM
NC
NO
*Door Position Sensor (Reed switch)
RED (open with door closed)
GREEN (closed with door closed)
BLACK
A/C
MAINS
POWER
SUPPLY
12VDC
or
24VDC
SWITCH or
ACCESS
CONTROL
+
-
+
-
1
+
2
-
3
N
O
4
C
5
N
C
Power
Supply
DOOR POSITION
SENSOR *
N/C – RED
COM – BLK
N/O - GRN
Voltage Jumper
12VDC
24VDC
Lock
Status
Switch
(Relay)