beautypg.com

Step 5 – SDC 350 NARROW LIINE EMLOCK User Manual

Page 3

background image

5. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the

door. Tap with a soft hammer to ensure proper alignment and engagement.

CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head
screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the
threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing

STEP 5

6. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock.

7. Test operation. When all is operating properly, tighten

all screws.

LED Status Indicator:
RED – Energized and Unsecure GREEN – Energized and Secure

P:\INSTALLATION INST\Electromagnetic Locks\INST-350.vsd REV -

02-12 Page 3

To maintain surface plating from corrosion:

Do not touch the lock face with your hands.
Clean lock face with Scotch-Brite pad by 3M (do not use
sandpaper).
Apply a thin film of rust inhibitor (LPS-3) on lock face.
Repeat application on armature plate.

COM

NC

NO

*Door Position Sensor (Reed switch)

RED (open with door closed)

GREEN (closed with door closed)

BLACK

A/C

MAINS

POWER

SUPPLY

12VDC

or

24VDC

SWITCH or

ACCESS

CONTROL

+

-

+

-

1

+

2

-

3

N

O

4

C

5

N

C

Power

Supply

DOOR POSITION

SENSOR *
N/C – RED

COM – BLK

N/O - GRN

Voltage Jumper

12VDC

24VDC

Lock
Status
Switch
(Relay)