Additional e75 programming, Reset the e75 to factory settings, Set unlock timer – SDC E75 STANDALONE ELECTRONIC LOCKSET User Manual
Page 5: Beep on keypress, Set the date, Set the time, Enable a user, Disable a user, Change a user group, Clear all programming
P:\INSTALLATION INST\ACCESS CONTROLS\E75\INST-E75.vsd REV A 05-13 Page 5
Reset the E75 to Factory Settings*
1) Remove power (Unplug the battery pack)
2) Short and hold the 2 Brn reset wires together
3) Apply power. (Plug in the battery pack)
The LED will Flash Red/Grn will light during the
initialization process. When initialization is complete, you
will here 3 beeps.
4) Remove power (Unplug the battery pack)
5) Disconnect and insulate the Brn Reset wires.
*
To test lock operation after a Hardware Reset and
before initialization, enter *741. This temporary code
will unlock the E75 for testing purposes. Once a lock
initialization has been performed (see page 1), this code
is no longer active until a hardware reset is performed
again A Hardware reset will erase all the users and
return the E75 back into the uninitialized factory
default condition.
Set Unlock Timer:
21# Seconds#
Example: Press 21# 03 #
Unlock timer is set for 03 seconds. (default)
Seconds = 03-20
Beep on Keypress :
62# Status #
Example 1: Press 62# 1#
The E75 will beep each time you press a key.
Status = 0 Disabled
1 Enabled (default)
Set the Date:
30# MMDDYY#
Example: Press 30# 011513 #
The date is set for January 15 th 2013
MM = 2 digit Month
DD = 2 digit Day
YY = 2 digit Year
Set the Time:
31# HH MM#
Example: Press 31# 1320 #
The time is now set to 1:20 PM.
HH = Hours (24hr format)
MM = Minutes (24hr format)
Enable a User:
26# User No.#
Example: Press 26# 04#
You have just re-enabled User #04 .
Disable a User:
27# User No.#
Example: Press 27# 04#
You have just disabled User #04 . It re-enable this user, use Function 26
Change a User Group:
04# User No.# New user Group
Example: Press 04# 05# 02#
You have just Changed User #05's group to Group 02.
Additional E75 Programming
Clear all Programming :
99# 000000 #
Example 1: Press 99# 000000 #
All user codes and programming is erased and settings are set to factory defaults. Lock
initialization and Lock ID are not cleared.