User programming – SDC E75 STANDALONE ELECTRONIC LOCKSET User Manual
Page 4
P:\INSTALLATION INST\ACCESS CONTROLS\E75\INST-E75.vsd REV A 05-13 Page 4
Quick Start
Programming Instructions
E75 EntryCheck
TM
Enter Programming Mode: #9# User No# User PIN #
1) Press #9# 01# 123456#
User 01 is the administrator and has full programming rights. 20 seconds of
inactivity will automatically return you from programming mode you to
operational mode.
Exit Programming Mode: **#
Press **#
Lock Initiation
When the lock is first installed or when after a hard reset has been performed, the E75 must be initialized and a lock ID must be
entered before you will be allowed to enter the program mode.
To test lock operation before initialization, enter *741. This temporary code will unlock the E75 for testing purposes. Once a lock
initialization has been performed, this code is no longer active until a hardware reset is performed which will erase all the users and
return the E75 back into the uninitialized factory default condition. Initialize the lock :
Add a User:
01# User No.# PIN Code # Pin Code # Group No.#
Example: Press 01# 04# 5555# 5555# 06#
You have just added User #04 with a PIN of 5555.
User 4 has also be assigned to group 06 (24/7 access).
Change a User PIN Code:
03# User No.# New PIN Code # New Pin Code #
Example: Press 03# 05# 1220# 1220#
You have just Changed User #05's Pin code to 1220
The Administrator’s PIN code must be 6 digits in length. All other PIN codes may be 4-6 digits in length
Delete a User:
02# User No.#
Example: Press 02# 04#
You have just Deleted User #04
User Programming
Add a Card:
06# User No.# Present Card #
Example: Press 06# 04# Present Card #
You have just added a card as User #4.
User 4 has also be assigned to group 06 (24/7 access).
Prox
Units
Only
1) Apply Power (Plug in the battery pack)
2) Press #9* 123456# 0001#
3) Press **#
The example enters a Lock ID of 0001. If Multiple locks are used with the Management
Software, Each lock must have it’s own Unique Lock ID (0002, 0003 etc)