Advanced Programming

Enter Programming Mode

Press # 12345

B B

LED

Before any function is performed, you must first Enter Programming Mode.

NOTE: It is important that you wait for the appropriate LED response before continuing to the next intermediate step.

After entering programming mode, you have 30 seconds to press any key before the unit automatically exits
programming mode.

Once a function # is entered, you have 5 seconds between intermediate steps. If you take too long and get a Red LED,
wait until you see the blue pulse every 2 seconds, and restart the function.

After completing any function, the BLUE LED will blink twice (1 flash per second) as confirmation. The unit will remain in
programming mode until you exit programming mode using Function 00, or by waiting 30 seconds for the automatic
timeout.

{The Blue LED will pulse once every two seconds while in programming mode.}

Function 00: Exit Programming Mode

Press 00

#

B

LED

B B

LED

Function 04: Add or Change a User Code

Press 04

User ID# Enter new User code

B

LED

B

LED

B B

LED

Example: 04 02 98765

B

LED

B

LED

B B

LED

Function 01: Change the Master Code / Change Code Length

Press 01

Length of Code Enter new Master code

Re-enter Length of Code

Re-enter Master Code

B

LED

B

LED

B

LED

B

LED

B B

LED

Example: 01

5 99999

5

99999

B

LED

B

LED

B

LED

B

LED

B B

LED

{Sets the code length = 5. Sets the Master Code to ‘99999’}

{Adds User ID 02 with code ‘98765’}

IMPORTANT:
User ID# ranges from 01 to 30.
User Codes must be same length as Master Code.
User Codes must be unique or they will be rejected.

Function 05: Delete All User Codes

Press 05

05

B

LED

{LED will pulse quickly, and then flash for 1 second}

IMPORTANT:
All codes (User ID 01 – 30) will be erased.
Master & Sub-Master Codes are not affected.

Function 06: Suspend Any Authorized User Code

Press 06

User ID#

B

LED

B B

LED

Example: 06 10

B

LED

{User code with User ID 10 is suspended}

IMPORTANT:
User ID# ranges from 01 to 30.
If User ID # is not an authorized user, an error will
occur.

B B

LED

Function 07: Restore Any Authorized User Code

Press 07 User ID#

Example: 07 10

B

LED

B B

LED

B

LED

B B

LED

{User code with User ID 10 is restored access}

IMPORTANT:
User ID# ranges from 01 to 30.
If User ID # is not an authorized user, an error will
occur.

Function 08: Suspend ALL Authorized User Codes

Press 08

08

B

LED

B B

LED

{All authorized user codes are suspended}

Function 09: Restore ALL Authorized User Codes

Press 09 09

B

LED

B B

LED

{All authorized users are restored access}

IMPORTANT:
Any users added after this function is activated, will
also be suspended.
Master & Sub-Master Codes are not affected.

P:\INSTALLATION INST\Access Controls\INST-295\INST-295.vsd REV C 10-13 Page 3