Advanced Programming
Enter Programming Mode
Press # 12345
B B
LED
Before any function is performed, you must first Enter Programming Mode.
NOTE: It is important that you wait for the appropriate LED response before continuing to the next intermediate step.
After entering programming mode, you have 30 seconds to press any key before the unit automatically exits
programming mode.
Once a function # is entered, you have 5 seconds between intermediate steps. If you take too long and get a Red LED,
wait until you see the blue pulse every 2 seconds, and restart the function.
After completing any function, the BLUE LED will blink twice (1 flash per second) as confirmation. The unit will remain in
programming mode until you exit programming mode using Function 00, or by waiting 30 seconds for the automatic
timeout.
{The Blue LED will pulse once every two seconds while in programming mode.}
Function 00: Exit Programming Mode
Press 00
#
B
LED
B B
LED
Function 04: Add or Change a User Code
Press 04
User ID# Enter new User code
B
LED
B
LED
B B
LED
Example: 04 02 98765
B
LED
B
LED
B B
LED
Function 01: Change the Master Code / Change Code Length
Press 01
Length of Code Enter new Master code
Re-enter Length of Code
Re-enter Master Code
B
LED
B
LED
B
LED
B
LED
B B
LED
Example: 01
5 99999
5
99999
B
LED
B
LED
B
LED
B
LED
B B
LED
{Sets the code length = 5. Sets the Master Code to ‘99999’}
{Adds User ID 02 with code ‘98765’}
IMPORTANT:
User ID# ranges from 01 to 30.
User Codes must be same length as Master Code.
User Codes must be unique or they will be rejected.
Function 05: Delete All User Codes
Press 05
05
B
LED
{LED will pulse quickly, and then flash for 1 second}
IMPORTANT:
All codes (User ID 01 – 30) will be erased.
Master & Sub-Master Codes are not affected.
Function 06: Suspend Any Authorized User Code
Press 06
User ID#
B
LED
B B
LED
Example: 06 10
B
LED
{User code with User ID 10 is suspended}
IMPORTANT:
User ID# ranges from 01 to 30.
If User ID # is not an authorized user, an error will
occur.
B B
LED
Function 07: Restore Any Authorized User Code
Press 07 User ID#
Example: 07 10
B
LED
B B
LED
B
LED
B B
LED
{User code with User ID 10 is restored access}
IMPORTANT:
User ID# ranges from 01 to 30.
If User ID # is not an authorized user, an error will
occur.
Function 08: Suspend ALL Authorized User Codes
Press 08
08
B
LED
B B
LED
{All authorized user codes are suspended}
Function 09: Restore ALL Authorized User Codes
Press 09 09
B
LED
B B
LED
{All authorized users are restored access}
IMPORTANT:
Any users added after this function is activated, will
also be suspended.
Master & Sub-Master Codes are not affected.
P:\INSTALLATION INST\Access Controls\INST-295\INST-295.vsd REV C 10-13 Page 3