background image

Beep Sounds During Auxiliary Relay

Default: No

Selects whether or not the keypad beeps during Auxiliary Relay
activation.

Press: 4 2 # Sound #

Sound=1 for Yes, =0 for No

Beep Sounds During Output #3

Default: No

Selects whether or not the keypad beeps during Output #3
activation.

Press: 4 3 # Sound #

Sound=1 for Yes, =0 for No

Beep Sounds During Output #4

Default: No

Selects whether or not the keypad beeps during Output #4
activation.

Press: 4 4 # Sound #

Sound=1 for Yes, =0 for No

Keypad Lockout Count

Default: 3 Tries

Sets the number or incorrect entry code attempts allowed
before the keypad “locks out”.

Press: 5 0 # Attempts #

Attempts=Number of attempts before lockout (2-7)

Anti-Pass Back Time

Default: No Anti-Pass Back

Sets the length of time an entry code will not function after it is
used.

Press: 5 1 # Minutes #

Minutes=Time in minutes (1-4), 0=No Anti-passback

RESETTING KEYPAD

Master Reset

CAUTION: Performing a master reset will clear the
entire memory of the 918 and return all programmable
options to the factory default values. ALL ENTRY
CODES WILL BE ERASED.

STEP 1 Disconnect power from the keypad.
STEP 2 Press and hold down the * and # keys.
STEP 3 Apply power to the keypad, continue holding the keys

down until the red indicator starts flashing

STEP 4 Release the keys. The red and yellow indicators will

remain lit until the process is complete, then the
yellow indicator will go out.

Resetting the Master Code

STEP 1 Remove the 918 from the wall..
STEP 2 Locate jumper at JP2. This jumper is used to reset

the master code.

STEP 3 With power applied to the keypad, remove the jumper

at JP2. The keypad will begin to beep, signaling that

the code has been reset.

STEP 4 Replace jumper on JP2

THE MASTER PROGRAMMING CODE IS NOW 123456.

Beeper Sound Level

The Keypad’s beeper can be set to high or low level.
Remove jumper JP1 to reduce beeper sound level.

Beep Sounds During Main Relay

Default: No

Selects whether or not the keypad beeps during Main Relay
activation.

Press: 4 1 # Sound #

Sound=1 for Yes, =0 for No

Solid-state Output #4 On-time

Default: 60 Seconds

Sets the length of time Output #4 activates when triggered.

Press: 2 4 # Seconds #

Seconds=Output time in seconds (0-60), 99=Toggle Mode

Beep Sounds on Keystrokes

Default: 1 Second

Selects whether or not the keypad beeps as each key is pressed.

Press: 4 0 # Sound #

Sound=1 for Yes, =0 for No

P:\INSTALLATION INST\Access Controls\INST-918\INST-918.vsd REV A 03-12 Page 6

Selects mode for Keypad LED Backlight

Default: 30 Seconds

Selects whether or not the keypad back light stays OFF, lights for 30
seconds when activated or stays ON.

Press: 52 # Output #

0 = Light always OFF

1 = 30 sec light when activated (default)

2 = Light always ON