D50 & D60 HEADER/ADAPTER
Form 169009
43
Model Year - 2009
e. Lower stand (F) by pulling spring loaded pin
(G). Release pin when stand at desired height.
f. Remove pin (H) from leg on both sides of
adapter.
g. Disconnect center link as follows:
1. For hydraulic adjuster, lift release (J) and
latch it in up position.
2. Extend center link cylinder to disengage
hook from header.
3. Prop up center link with a pin or equivalent
tool.
4. For mechanical link, remove pin (K) to
release link. Replace pin.
NOTE
Feeder house may need to be raised or
lowered, or length of link adjusted, to
relieve load on link.
h. Disconnect sickle and draper drive hydraulic
hoses. Install caps and plugs on fittings.
i. If quick disconnects are installed, disconnect as
follows:
1. Line up slot (L) in collar with pin (M) on
connector.
2. Push collar toward pin and pull connector to
disengage.
3. Install plugs or caps on hose ends (if
equipped).
j. Disconnect electrical connector by turning collar
counterclockwise and pulling connector to
disengage.
k. Store and secure hoses on adapter.
(continued next page)
K
M
L
J
DRAPER DRIVE
RETURN
ELECTRICAL
KNIFE DRIVE
CASE DRAIN
(DOUBLE KNIFE)
QUICK DISCONNECTS SHOWN
F
G
H