Opticon PHL 1700 User Manual
Page 13
U
SER
’
S MANUAL
PHL 1700
LASER TERMINAL
/ IRU 1700
CRADLE
13
Exercise caution at all times when
working with AC-powered equipment.
Turn off your devices before
installation.
Because of the special pin-out of the
connectors, use the cables supplied
by the manufacturer.
When you need another cable for a
certain device, that is not supplied,
contact your supplier to purchase the
right cable. In case another cable is
used, take notice of the pin-out
specifications further in this manual.
2.6.1 Power supply for cradle
Make sure that you use the right
power supply.
Use for model T and SV: 9V DC adaptor
Use for model TC: 5V DC adaptor
2.6.2 Dip switch settings on cradle
Setting the DIP switches on or off will result in
enabled or disabled functions of the cradle.
(see table on next page)
Make sure power is switched off.
Open the cover of the DIP switches on the
bottom of the cradle in order to reach the
DIP switches.
!
!
!
!
!
2.6.3 Connect cradle to computer/modem
Connection sequence (see diagram and
dipswitch settings on next page)
Shutt off the computer.
Make sure cradle is disconnected.
Place the cradle in normal office conditions,
avoid a place under strong light (1).
Set proper baudrate on cradle (2), use
same baudrate as set on computer.
Connect the interface cable (3).
Connect the power supply (4) and power up
by power switch.
Power up the computer.
2.6.4 Connect network of cradles
(see diagram on next page)
Only 1 cradle in the network will be
connected to the PC through one RS232
cable. On this cradle the DIPswitch for
RS232 connection must be enabled.
Through this connection all cradles can
communicate to the PC.
A maximum of 16 cradles can be connected
in a network through RS485 cables. For the
cradles that are not directly connected to
the PC the DIPswitch for RS232 connection
must be set to off.
All cradles need to have the same baudrate,
for model SV to be set by dipswitch.
The first and the last cradle in the network
must have the termination resistors set by
DIPswitch.
2.6.5 Terminal on cradle
Do not place any other product than
the PHL1700 terminal in the IRU1700
cradle.
Place the terminal on the cradle as shown in
the illustration:
(Indicator on cradle: green LED)
!
2.6 INSTALLING IN A SYSTEM