beautypg.com

MTS SWIFT 30 Sensor User Manual

Page 93

background image

Test Track Vehicle

SWIFT 30 Sensors

Installing the Transducer

93

Note

The wheel must rotate one-half revolution in the same direction and then
pass over the encoder index point before data collection is started.

12. Perform

, “Verifying the Quality of the Zero Procedure,”

on page 95.

13. Look at your data acquisition system to verify that the SWIFT sensor is

gathering data.

If Zero Algorithm=3

When you zero the TI, you want the vehicle to be fairly level and the transducer
to be as close to plumb as practical.

1. Install the SWIFT sensor(s) and data collection equipment on the vehicle.

2. Connect all cables and turn on the power to the TI boxes.

3. Let the TI boxes and transducers warm up for 15–20 minutes.

4. Run the TISTATUS program to compare the supply voltages to the

reference voltages.

Type: TIstatus

If the supply voltages vary more than 0.5 V from the reference voltages,
there is a power supply problem that must be resolved before you can
continue.

5. Verify that the calibration file is set up correctly.

A. Download the calibration file (xxxxx.cal) to the computer from the

MTS Disk that corresponds to the serial number of the transducer that

you are setting up.

B. If necessary, modify the zero algorithm and angle mode to fit the

application/use requirements as described in

, “Edit the Calibration

File,”

on page 66.

C. The EncoderSize parameter should be omitted or set to EncoderSize=1

D. Download the calibration file to the TI box.

Note

If it becomes necessary to change the zero algorithm or angle mode
after downloading the file to the TI, you can do so by using the
TISETZERO utility, as described in

, “TISETZERO – Transducer Interface

Set Zero Method,”

on page 55.

6. Elevate the vehicle with a lift, or raise each corner with a jack.

7. Perform the zero procedure on each corner of the vehicle. Both the angle

and bridge zeros are computed by rotating the tire.