Specifications, Specifications 25 – MTS SWIFT 30 Sensor User Manual
Page 25
Specifications
SWIFT 30 Sensors
Hardware Overview
25
Specifications
SWIFT 30 Transducer Performance
P
ARAMETER
S
PECIFICATION
Use
SWIFT 30 A (aluminum) for
SWIFT 30 T (titanium) for
low weight, high sensitivity
high fatigue life, durability
Maximum usable rpm
2,200
Maximum speed
240 kph (150 mph)
fits rim size (usable range)
12–15 inch
*
* A special flange configuration is required for a 12 inch wheel. Larger diameter rims can be used,
providing that overall clearance from brake calipers and suspension components is maintained.
Maximum hub bolt circle diameter
accommodates M12 or 1/2 inch studs
120.65 mm (4.75 in)
Input voltage required
10–17 VDC
Input power required per transducer
30 W maximum (22 W typical)
Output voltage ± full scale calibrated load
±10 V
†
† Load impedance >1 k
Ω
; 0.01 µF (maximum) load capacitance.
SAE J328 rated load capacity
Aluminum
Titanium
6.5 kN (1,460 lbf)
10.7 kN (2,400 lbf)
Standard Maximum Calibrated Load Rating
‡
‡ The actual calibrated range may be different based on individual customer requirements. Consult the
calibration range sheet that accompanies each transducer for the correct calibration range.
Longitudinal force (Fx)
±28 kN (±6,295 lbf)
±50 kN (±11,240 lbf)
Lateral force range (Fy)
±23 kN (±5,170 lbf)
±40 kN (±8,990 lbf)
Vertical force range (Fz)
±28 kN (±6,295 lbf)
±50 kN (±11,240 lbf)
Overturning moment (Mx)
±5 kN•m (±44,255 lbf•in)
±9 kN•m (±79,660 lbf•in)
Driving/braking moment (My)
±7.5 kN•m (±66,380 lbf•in)
±13 kN•m (±115,060 lbf•in)
Steering moment (Mz)
±5 kN•m (±44,255 lbf•in)
±9 kN•m (±79,660 lbf•in)
Resolution (analog system)
Infinite
Noise level (peak-to-peak 0-500 Hz)
15 N (3.4 lbf)
25 N (5.6 lbf)
Performance accuracy
Nonlinearity
1.0% full scale
Hysteresis
0.5% full scale
Modulation
§
§ Typical value on most steel rims. Aluminum rims typically have slightly higher modulation, but at a lower
added weight.
≤3.0% reading
Cross talk
#
# Each SWIFT sensor is calibrated on an MTS calibration machine. MTS provides complete documentation
of calibration values for each SWIFT unit
1.5% full scale
Maximum operating temperature
Low level amplifiers
Transducer interface
70°C (158°F)
50°C (122°F)