6
Storage Temperature
-20 to 70 C
Ambient Operating Temperature
0 to 50 C (up to 6 kHz carrier, derate above 6 kHz)
Ambient Humidity
< 95% (non-condensing)
Maximum Altitude
3300 ft (1000 m) above sea level (without derating)
Input Line Voltages
208/240 Vac, 400/480 Vac, 480/590 Vac
Input Voltage Tolerance
+10%, -15%
Input Frequency Tolerance
48 to 62 Hz
Output Wave Form
Sine Coded PWM
Output Frequency
0 - 240 Hz (consult factory for higher output frequencies)
Carrier Frequency
4 kHz to 10 kHz
Service Factor
1.00 (up to 6 kHz carrier, derate above 6 kHz)
Efficiency
Up to 98%
Power Factor (displacement)
0.96 or better
Overload Current Capacity
150% for 60 seconds, 180% for 30 seconds
Speed Reference Follower
0-10 VDC, 4-20 mA
Control Voltage
15 VDC
Power Supply for Auxiliary Relays
50 mA at 12 VDC
Analog Outputs
0 - 10 VDC or 2 - 10 VDC: Proportional to frequency or load
Digital Outputs
Open-collector outputs: 50 mA at 30 VDC
4.0
SCD SPECIFICATIONS
Supply Voltage
11 to 25 VDC
Current Consumption (max)
50 mA @ 11 VDC
Baud Rates and Max Distance
125 kbps - 500 m (1640 ft)
250 kbps - 250 m (820 ft)
500 kbps - 100 m (328 ft)
4.1
DEVICENET
TM