Lenze SCD Series User Manual
Page 35

32
FACTORY
NO.
PARAMETER NAME
RANGE OF ADJUSTMENT
DEFAULT
(NOTE 1)
C00
DNET NODE ADDRESS
0 - 63
63
C01
DNET BAUD RATE
125 kbps (0), 250 kbps (1), 500 kbps (2)
125 kbps (0)
C02
DNET LOSS ACTION
FAULT & STOP (0), IGNORE (1), AC TECH (2)
FAULT & STOP (0)
C03
DNET OUTPUT ASSY
1 BASIC CONTACTOR (1),
20 BASIC SPEED
2 BASIC OVERLOAD (2),
CONTROL (6)
3 BASIC MOTOR STARTER (3),
4 EXTENDED CONTACTOR (4),
5 EXTENDED MOTOR STARTER (5),
20 BASIC SPEED CONTROL (6),
21 EXTENDED SPEED CONTROL (7),
100 EXTENDED SPEED CONTROL Hz (8)
C04
DNET INPUT ASSY
50 BASIC OVERLOAD (1),
70 BASIC SPEED
51 EXTENDED OVERLOAD (2)
CONTROL (6)
52 BASIC MOTOR CONTROL (3),
53 EXTENDED MOTOR CONTROL 1 (4),
54 EXTENDED MOTOR CONTROL 2 (5),
70 BASIC SPEED CONTROL (6),
71 EXTENDED SPEED CONTROL (7),
101 EXTENDED SPEED CONTROL Hz (8),
102 CUSTOM ASSEMBLY (9)
C05
DNET CUSTOM ASSY 0
0 - 150
0
C06
DNET CUSTOM ASSY 1
0 - 150
0
C07
DNET CUSTOM ASSY 2
0 - 150
0
C08
DNET CUSTOM ASSY 3
0 - 150
0
C09
DNET MOTOR TYPE
NON-STANDARD MOTOR (0), PM DC MOTOR (1),
SQUIRREL CAGE
FC DC MOTOR (2), PM SYNCH. MOTOR (3),
INDUCTION (7)
FC SYNCH. MOTOR (4), SWITCHED RELUCT. (5),
WOUND ROTOR INDUCTION (6),
SQUIRREL CAGE INDUCTION (7),
STEPPER MOTOR (8), SINUSOIDAL PM BL (9),
TRAPEZOIDAL PM BL (10)
C10
DNET DIAGNOSTICS
(READ ONLY)
(N/A)
PARAMETER MENU (CONT’D)