Programming, 8 system variables and flags summary, 1 system variables – Lenze E94P PositionServo with MVOB User Manual
Page 44

42
L
PM94H201B_13xxxxxx_EN
Programming
2.8
System Variables and Flags Summary
2.8.1 System Variables
Section 3.2 provides a complete list of the system variables. Every aspect of the PositionServo can be controlled by
the manipulation of the values stored in the System Variables. All System Variables start with a “VAR_” followed by the
variable name. Alternatively, System Variables can be addressed as an @NUMBER where the number is the variable
Index. The most frequently used variables also have alternate names as listed in Table 11.
Table 11: System Variables
Index
Variable
Access Variable Description
Units
181
ACCEL
R/W
Acceleration for motion commands
User Units/Sec
2
71
AIN1
R
Analog input. Scaled in volts. Range from -10 to +10 volts
V(olt)
72
AIN2
R
Analog input 2. Scaled in Volts. Range from -10 to +10 volts
V(olt)
88
AOUT
R/W
Analog output. Value in Volts. Valid range from -10 to +10 (V)
(2)
V(olt)
215
APOS
R/W
Actual motor position
User Units
190
APOS_PLS
R/W
Actual Motor Position
Encoder Counts
182
DECEL
R/W
Deceleration for motion commands
User Units/Sec
2
83
DEXSTATUS
R
Drive Extended Status Word
-
54
DSTATUS
R
Status flags register
-
DFAULTS
R
Fault code register
-
245
HOME
W
Start Homing (pre-defined homing)
-
INDEX
R
Lower 8 bits are used. See ASSIGN statement for details.
-
184
INPOSLIM
R/W
Maximum deviation of position for INPOSITION Flag to remain set
User Units
65
INPUTS
R
Digital Inputs states. The first 12 bits correspond to the 12 drive inputs
-
139
IREF
W
Internal Reference: Velocity / Torque
RPS/A
187
MECOUNTER
R
Master Encoder Counts (Master Encoder Input)
Encoder Counts
180
MAXV
R/W
Maximum velocity for motion commands
User Units/Sec
140-171
NV0 - NV31
R/W
User Network Variables
-
66
OUTPUTS
R/W
Digital outputs. Bits #0 to #4 represent outputs 1 through 5
-
216
PERROR
R
Position Error
Feedback Pls
191
PERROR_PLS
R
Position Error
User Units
48
PGAIN_D
R/W
Position loop D-gain
-
47
PGAIN_I
R/W
Position loop I-gain
-
49
PGAIN_ILIM
R/W
Position loop I gain limit
-
46
PGAIN_P
R/W
Position loop P-gain
-
188
PHCUR
R
Motor phase current
A(mpere)
183
QDECEL
R/W
Quick Deceleration for STOP MOTION QUICK statement
User Units/Sec
2
213
RPOS
R
Registration position. Valid when system flag F_REGISTRATION set
User Units
212
RPOS_PLS
R
Registration position
Feedback Pls
218
TA
R
Commanded acceleration
User units/Sec
2
214
TPOS
R/W
Theoretical/commanded position
User Units
219
TPOS_ADV
W
Theoretical/commanded position advance
Feedback Pls
189
TPOS_PLS
R/W
Theoretical/commanded position
Feedback Pls
217
TV
R
Commanded velocity in
User Units/Sec
186
UNITS
R/W
User Units scale.
(1)
UserUnits/Rev
185
VEL
R/W
Set Velocity when in velocity mode
User Units/Sec
44
VGAIN_P
R/W
Velocity loop P-gain
-
45
VGAIN_I
R/W
Velocity loop I-gain
-
100-131
V0 - V31
R/W
User Variables
(1)
When a “0”, (zero), value is assigned to the variable “UNITS”, then “USER UNITS” is set to QUAD ENCODER COUNTS.
(2)
Any value outside +/- 10 range assigned to AOUT will be automatically trimmed to that range.