Activation/deactivation of password protection – Lenze EMZ9371BC User Manual
Page 85

Parameterisation 8200 vector/8200 motec
Activation/deactivation of password protection
EDK9371BC DE/EN/FR 3.1
85
l
H1 Parametrierung 8200−9371BC_6L
Activation/deactivation of password protection
)
Note!
ƒ
If the password protection is activated (C0094 = 1 ... 9999) only the user
menu can be freely accessed.
ƒ
To get into the other menus you must enter the password first.
ƒ
Please observe that also the password−protected parameters will be
overwritten when parameter sets are transferred to other controllers. The
password will be transferred, too.
ƒ
Do not forget your password! If you cannot remember the password, it can
only be reset via PC or a bus system.
Activation of password protection
Step
Keys
Action
1.
Select the submenu 2.1 "ALL" in
the menu 2
z y Z Y
Change to the submenu "ALL" with the
arrow keys
2.
Change to the code level
Z
Display of code C0001 "Setpt setup"
3.
Select C0094
z
Display of code C0094 "User password"
4.
Change to parameter level
V
Display "0" (no password protection)
5.
Set password
A
z
Select password (1 ... 9999)
B
T V
Confirm password
6.
Change to the code level
A
V
Display of operation level
B
V
Display of C0094 and "User password"
7.
Change to menu 1 "USER
menu"
Y Y y
The password protection is active now:
l
Every time you want to leave the user menu, "Enter password" is displayed.
l
If you enter the correct password and confirm it with
T V
all menus are freely accessible
again.