Diagnostics – Lenze EMZ9371BC User Manual
Page 116

Parameterisation 9300 series
Diagnostics
EDK9371BC DE/EN/FR 3.1
116
l
Parametrierung 9300−9371BCme93
Diagnostics
In the "Diagnostic" menu the two submenus "Actual info" and "History" contain all codes
for
ƒ monitoring the drive
ƒ fault/error diagnosis
In the operating level, more status messages are displayed. If several status messages are
active, the message with the highest priority is displayed.
Priority
Display
Meaning
1
GLOBAL DRIVE INIT
Initialisation or communication error between
keypad and controller
2
XXX − TRIP
Active TRIP (contents of C0168/1)
3
XXX − MESSAGE
Active message (contents of C0168/1)
4
Special device states:
Switch−on inhibit
5
Source for controller inhibit (the value of C0004 is displayed simultaneously):
STP1
9300 servo:
Terminal X5/28
ECSxS/P/M/A: Terminal X6/SI1
STP3
Operating module or LECOM A/B/LI
STP4
INTERBUS or PROFIBUS−DP
STP5
9300 servo,
ECSxA/E:
System bus (CAN)
ECSxS/P/M:
MotionBus (CAN)
STP6
C0040
6
Source for quick stop (QSP):
QSP−term−Ext
The MCTRL−QSP input of the MCTRL function block
is on HIGH signal.
QSP−C0135
Operating module or LECOM A/B/LI
QSP−AIF
INTERBUS or PROFIBUS−DP
QSP−CAN
9300 servo,
ECSxA:
System bus (CAN)
ECSxS/P/M:
MotionBus (CAN)
7
XXX − WARNING
Active warning (contents of C0168/1)
8
xxxx
Value below C0004