Lenze EMZ9371BC User Manual
Page 82

Parameterisation 8200 vector/8200 motec
Transmit parameter sets
EDK9371BC DE/EN/FR 3.1
82
l
H1 Parametrierung 8200−9371BC_6L
Action
Key sequence
Step
l
Copy individual parameter sets (PARx and, if applicable, FPAR1) to the standard device:
– Standard device with
function module
Application I/O,
INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
z
Copy PAR1 and FPAR1:
ð
Set "71" "Key−>FP1&PAR1"
Copy PAR2 and FPAR1:
ð
Set "72" "Key−>FP1&PAR2"
Copy PAR3 and FPAR1:
ð
Set "73" "Key−>FP1&PAR3"
Copy PAR4 and FPAR1:
ð
Set "74" "Key−>FP1&PAR4"
– Standard device
including all other
function modules or
standard device without
any function modules
Copy PAR1:
ð
Set "11" "Keypad−>PAR1"
Copy PAR2:
ð
Set "12" "Keypad−>PAR2"
Copy PAR3:
ð
Set "13" "Keypad−>PAR3"
Copy PAR4:
ð
Set "14" "Keypad−>PAR4"
7.
Start copying
T V
The selected parameter sets are copied to
the standard device or to the function
module.
"LOADING..." is displayed.
If "LOADING ..." goes out, the copying
process has been completed.
8.
Change to the code level
A
V
The operating level is displayed
B
V
"Param managm" is displayed in C0002
9.
Enable the controller
U
The drive restarts