Restoring default (as delivered) settings
Step
Key sequence
Action
1.
Connect the keypad to the
standard device
2.
Inhibit the controller
S
The drive coasts
3.
Select the "Load/Store"
submenu 7.1 in the "Param
managm" menu 7
z y Z Y
Change to the "Load/Store" submenu
using the arrow keys
4.
Change to the code level
Z
"Param managm" is displayed in C0002
5.
Change to the parameter level
V
"0" and "READY" are displayed
6.
Select the correct copy function
The settings stored in the standard
device or in the function module are
overwritten.
l
Load parameter sets (PARx) into the standard device:
– Restore the delivery
status in the selected
parameter set of the
standard device
z
Load PAR1:
ð
Set "1" "Keypad−>PAR1"
Load PAR2:
ð
Set "2" "Keypad−>PAR2"
Load PAR3:
ð
Set "3" "Keypad−>PAR3"
Load PAR4:
ð
Set "4" "Keypad−>PAR4"
l
Load the parameter set (FPAR1) into the fieldbus function module:
– Restore the delivery
status in the fieldbus
function module
z
Load FPAR1
ð
Set "31" "Keypad−>FPAR1"