1 measuring signal vs. pressure, P = 10, U = c + log – INFICON Gemini ATM to Ultra-High Vacuum Gauge User Manual
Page 15: Valid in the range 1×10, Mbar < p < 1×10, Mbar 7.5×10, Torr < p < 7.5 ×10, Torr 1×10, Pressure p measurement signal u [v
tina83e1-a (2014-02)
15
2.1
Measuring Signal vs. Pressure
Measurement range 1.5 … 8.5 V (3MAx-xxx-0x0N)
1E–01
1E+00
1E–06
1E–07
1E–08
1E–09
1E–10
0.0 0.5 1.0 1.5
2.5
3.5
4.5
5.5
6.5
7.5
8.5
9.5
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
se
ns
or
er
ro
r
Pressure p
Measurement signal U [V]
1E–02
1E–03
1E–04
1E–05
un
de
rr
an
ge
Pa
mbar
torr
o
ve
rra
ng
e
p = 10
(U-c)
⇔
U = c + log
10
p
valid in the range 1×10
-9
mbar < p < 1×10
-2
mbar
7.5×10
-10
Torr < p < 7.5 ×10
-3
Torr
1×10
-7
Pa < p < 1 Pa
mbar Pa Torr
c 10.5 8.5 10.625
where p pressure
U measurement signal
c constant (pressure unit dependent)
See also other documents in the category INFICON Equipment:
- TGF10 Tracer Gas Filler (36 pages)
- Sensistor ILS500 F Leak Detection Filler (90 pages)
- T-Guard Leak Detection Sensor (85 pages)
- T-Guard Leak Detection Sensor Interface description (40 pages)
- Sensistor ISH2000P Hydrogen Leak Detector, Panel Model (51 pages)
- Sensistor ISH2000 HySpeed Hydrogen Leak Detector (54 pages)
- LDS3000 Modular Leak Detector (52 pages)
- LDS3000 Modular Leak Detector Interface description (56 pages)
- BM1000 Bus module (14 pages)
- I/O1000 I/O module (18 pages)
- CU1000 Control unit (24 pages)
- Helium Leak Detector Modul1000 (130 pages)
- Helium Leak Detector Modul1000 Interface description (40 pages)
- UL5000 Dry Helium Leak Detector (108 pages)
- UL5000 Dry Helium Leak Detector Interface description (14 pages)
- UL1000 Fab Dry Helium Leak Detector (119 pages)
- HLD6000 Refrigerant Leak Detector (76 pages)
- HLD6000 Refrigerant Leak Detector Interface Description (40 pages)
- IO1000 I/O module (18 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector (92 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector Interface description (36 pages)
- Sensistor XRS9012 Hydrogen Leak Detector User Manual (28 pages)
- Sensistor XRS9012 Hydrogen Leak Detector Maintenance manual (14 pages)
- Extrima Ex-certified Hydrogen Leak Detector (62 pages)
- Sensistor ILS500 Leak Detection System (107 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (108 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (58 pages)
- Sensistor Sentrac Hydrogen Leak Detector (86 pages)
- Protec P3000(XL) Helium Leak Detector (132 pages)
- Pilot Plus Vacuum Gauge (2 pages)
- CO Check Carbon Monoxide Meter (2 pages)
- GAS-Mate Combustible Gas Leak Detector (12 pages)
- Whisper Ultrasonic Leak Detector (8 pages)
- Vortex AC Refrigerant Recovery Machine 115V (20 pages)
- Vortex AC Refrigerant Recovery Machine 230V (16 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (2 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (44 pages)
- D-TEK CO2 Refrigerant Leak Detector (12 pages)
- TEK-Mate Refrigerant Leak Detector (12 pages)
- Compass Refrigerant Leak Detector (12 pages)
- D-TEK Select Refrigerant Leak Detector (12 pages)
- Explorer Portable Gas Chromatograph (369 pages)
- MicroFID II Portable Flame Ionization Detector (89 pages)
- DataFID Portable Flame Ionization Detector for Landfill Emissions Monitoring (91 pages)
- Hydrostik Hydrogen Fuel Cylinder Installation (7 pages)