3. Press Ð or Ï to choose DMX FAIL menu.

Press ENT.

4. The screen shows:

GENERAL

DMX FAIL

[HOLD]

5. Use Í or Î to select one of the 3 options

available:

RESET:

sets all dimmers to zero after 5
seconds

HOLD:

maintains the last valid DMX
levels until DMX is restored

BACKUP: selects dimmer levels set-up

through the PRESETS memory
facility

6. Press ENT to leave the menu and record

the changes or EXIT (to leave the
previous settings unchanged).

Note: If BACKUP has been set, do not forget to

pre-set the relevant DMX backup state.

6.5.4 To set-up DMX Backup preset:

1. Press INST.
2. Press Ð or Ï to choose DMX BACKUP

menu. Press ENT.

3. The screen shows:

L: 242V

CH:T123456 00

A


4. Use Í or Î to select a channel number

(active channel number is underlined) or T
if all channels are to be set together.

5. Press Ï or Ð to adjust the backup level.

The dimmer output is live while the backup
levels are adjusted.

6. Press ENT to leave the menu and record

the changes or EXIT (to leave the
previous settings unchanged).

6.5.5 To set-up a DMX Minimum reset
In order to reduce dynamic filament noise in some
types of 120V Par lamps, it is sometimes necessary
to use a low preheat level. DMX minimum reset is
the automatic means to switch any preheat levels off
when DMX is not present (i.e. when the control desk
is switched off, but the dimmers remain on).

1. Press INST.

2. Press Ð or Ï to choose GENERAL

SETTINGS menu.
Press ENT.

3. Press Ð or Ï to choose MIN RESET

menu. Press ENT.

4. The screen shows:

GENERAL

MIN RESET:

[OFF]

5. Use Ï or Ð to select either AUTO

(preheat switches off when DMX is off) or
OFF (preheat runs continuously).

6. Press ENT to leave the menu and record

the changes or EXIT (to leave the
previous settings unchanged).

6.6 Serial address

The DimSTAT PC address which shown on the
output screen as A:XXX is the unique number which
is used by network to identify each dimmer unit for
the purpose of reporting status information and for
transferring data between the dimmer unit and PC. If
a dimmer unit is removed from the network and
replaced by another, DimSTAT will automatically
prompt for an update of configuration information
when the PC number is entered. DimSTAT identifies
the new unit on the network, and prompts the
operator to download the previous characteristics file
from the PC to the new dimmer. The PC number is
associated with a unique factory serial number
which is permanently stored in the dimmer. An
Autoreload function is also provided to reinstate the
PC address after a factory reset.

6.6.1 To set-up a serial address:

1. Press INST.
2. Press Ð or Ï to choose DIMSTAT

ADDRESS menu. Press ENT.

3. The screen shows:

ADDRESS: [001]

AUTO-RELOAD NO


4. Press Ï or Ð to set the address number

between 001 and 255.

5. Press Î to select auto-reload options of

YES or NO.

6. Press ENT to leave the menu and record

the changes or EXIT (to leave the
previous settings unchanged).