Built-in protection, Accessories, Status indication – ElmoMC SimplIQ Digital Servo Drives-Whistle Installation Guide User Manual
Page 55: Automatic procedures
Whistle and Tweeter Installation Guide
Technical Specifications
MAN-WHTWIG (Ver. 1.604)
55
4.1.7.
Built-In Protection
•
Software error handling
•
Abort (hard stops and soft stops)
•
Status reporting
•
Protection against:
Shorts between motor power outputs
Shorts between motor power output and power input/return
Failure of internal power supplies
Over temperature
•
Cont. temperature measurement. Temp can be read on the fly, Warning can be
initiated X degrees before temp disable is activated.
Over/Under voltage
Loss of feedback
Following error
Current limits
4.1.8.
Accessories
•
External heatsink (Whistle). See Section 3.4.1 for more details. Catalog number:
WHI-HEATSINK-2.
•
Evaluation Board. See Section 3.16 for a picture and more details. Catalog number:
EVA-WHI/GUI/BEL.
•
Cable Kit. See Section 3.16 for more details. Catalog number: CBL-EVAUNIKIT01.
4.1.9.
Status Indication
•
Output for a bi-color LED
4.1.10. Automatic Procedures
•
Commutation alignment
•
Phase sequencing
•
Current loop offset adjustment
•
Current loop gain tuning
•
Current gain scheduling
•
Velocity loop offset adjustment
•
Velocity gain tuning
•
Velocity gain scheduling
•
Position gain tuning