The CIDRA Corporation SONARtrac
TM
Model HD VF-100 Flow
Monitoring System (High Dispersion Volumetric Flow) is used to
provide accurate and reliable process flow measurements for difficult
to characterize solid/liquid mixtures and challenging sand/rock slurry
flows with varying velocities and densities within process pipes. The
SONARtrac
TM
HD VF-100 utilizes patented array processing
techniques to listen to and interpret flow turbulence generated by fluid
flow. The clamp-on design eliminates the need for cutting pipe or
interrupting process flow during installation.
The SONARtrac
TM
HD VF-100 consists of a common transmitter and
sensor heads sized for different pipe diameters.
SONARtrac
TM
process meters certified for use in hazardous areas are
rated for use in Class I, Division 2, Groups A, B, C, and D
environments (per US and Canadian standards).
This manual covers the basic installation and setup of the
SONARtrac
TM
HD VF-100 Flow Monitoring System. In all cases, local
safety and operating practices take precedence over the information
contained within this document.
For additional information, contact your local sales agent or CiDRA
Corporation Customer Support by telephone at 1-877-243-7277
(1-877-CIDRA77) or by E-Mail at [email protected]
1.1
Sensor Head Description and Function
The SONARtrac
TM
sensor head contains no moving parts. The sensor
head includes a sensor band and a fiberglass or stainless steel cover
assembly to protect the sensor band. The sensor band is wrapped
around and clamped onto the process pipe. A multi-conductor cable
electrically connects the sensors to an electronic module mounted in
the cover assembly. Signals from the electronic module exit through a
NEMA 4X rated connector mounted to the outer surface of the cover
assembly.
1.2
Transmitter Description and Function
The SONARtrac
TM
transmitter receives electrical signals from the
sensor head. The signals are processed using SONARtrac
TM
array
processing firmware that displays the calculated results on an integral
LCD screen. Results can also be transmitted using the 4–20mA
analog output, pulse output, alarm output or the RS-485/232 digital
output. The electronic assembly is housed in a rugged NEMA 4X
enclosure.