A1.9
Sensor Band Compatibility
The sensor band assemblies are interchangeable with all sensor head
cover assemblies of the same pipe diameters. Meter calibration
factors are included for each sensor band assembly. All sensor head
assemblies, independent of pipe size, are compatible with all
transmitters.
A1.10 Humidity
Limits
Transmitter: 0 – 100%
A1.11
Analog Output Adjustment
Two separate 4-20mA output signals scalable over stated range of
meter. Primary 4-20mA output HART compatible.
A1.12
Auxiliary Output Function
Serial Communication (RS-232/485), Pulse Relay, Alarm Relay
A1.13
Analog Output Test
Yes (under Diagnostic Menu)
A1.14 Software
Lockout
Yes (under Customize Menu)
A1.15
Hazardous Area Classification
Systems rated for use in Class I, Division 2, Groups A, B, C, and D
use will be specifically labeled for use in those environments.
Installation must be in accordance with Control Drawing 20332-01 as
shown in Appendix C of this manual. Updated information can be
found on the CiDRA web site at www.cidra.com.