A2

HD VF-100 PERFORMANCE SPECIFICATIONS

A2.1 Turn-on

Time

30 minutes to rated accuracy from power up

25 seconds from power interruption

A2.2 Start-up

Time

25 seconds from zero flow

A2.3

Low / High Flow Cutoff

Adjustable between 3 and 30 ft/sec. At process flow rates below and
above these values, the output will register a ‘max flow’
indication.

A2.4 Flow

Rate

Range

SONARtrac

TM

is capable of measuring signals from process fluids

traveling at velocities between 3 ft/s and 30 ft/s (1.0 m/s to 10 m/s).
This capability is for both forward or reverse flow directions.

A2.5 Accuracy

Flow rate accuracy is +/-1.0% of flow rate from 3 to 30 ft/sec (1 to
10m/s).

A2.6 Repeatability

+/- 0.3 % of reading

A2.7 Update

Rate

2 seconds