Sensor Assembly Cable Connection
Remove the tape (if it was used) that was temporarily installed to
retain the sensor connector under the cover access panel. Remove
the factory installed shorting plug (if so equipped) from the sensor
cable connector. Place the shorting plug in the holder in the
transmitter housing. (It will be used if sensor removal from the pipe is
necessary.) Install the sensor assembly cable connector into the
mating receptacle located inside the access cover plate on the sensor
upper cover as shown below. The connector is installed such that the
connector key faces away from the pipe. Push the connector into the
mating receptacle. The locks on the receptacle will engage to keep
the plug from pulling out. Ensure the connector is fully engaged.
Note:
Use care to ensure the sensor cable connector goes on
squarely to minimize risk of damaging the contacts.
Figure 28
Sensor Assembly Cable Installation
Connector locks
Sensor cable
access port
Sensor cable with key
positioned up away from pipe