Data transmission in a udp slave(server) mode, 4 assigning new ip address with arp commands, Fig. 32 – Atop Technology SE5002 User manual User Manual

Page 28: Fig. 33

background image

User manual Version 1.3

ABLELink

®

Ethernet Serial Server SE5002

Copyright © 2006 Atop Technologies, Inc.

All rights reserved. Designed in Taiwan.

-

27

-

2.

Slave (Server) Mode:To establish a connection using unicast or broadcast data

from one or multiple

host computer to a serial device.(Fig. 32)
Notes:The configuration is limited by the Local Listening Port (For example, on the SE5002 listening the port
is 4660 which receives data from the Host Computer).

HUB

TCP/IP Network

Host Computer #1

IP: 192.168.1.3

Destination IP 192.168.1.1

Destination Port 4660

Host Computer#2
IP: 192.168.1.100

Destination IP 192.168.1.1

Destination Port 4660

Host Computer #3

IP: 192.168.1.200

Destination IP 192.168.1.1

Destination Port 4660

Host Computer #4

IP: 192.168.1.254

Destination IP 192.168.1.1

Destination Port 4660

Serial Device 1

Serial Line

SE5002

IP 192.168.1.1

Listening port 4660

UDP datagram

Fig. 32. Data Transmission in a UDP Slave(server) Mode

3.4 Assigning new IP Address with ARP commands

ARP (address resolution protocol) commands can be used to assign a static IP address on SE5002 using
its hardware MAC (media access control) address. The MAC address"0060E9-xxxxxx" is printed on the rear
side of device . The following shows how it works on MS-DOS command prompt window.
Example: change IP from 10.0.50.100 to 10.0.50.101,and MAC address being 00-60-e9-11-11-01

Step1: Add the new host IP to the ARP table
Î Open Ms-DOS command prompt window
Î Input

arp -s 10.0.50.101 00-60-E9-11-11-01(Fig. 33)

Fig. 33. Ms-DOS command prompt window: add host computer IP to ARP table

Step2: Change to the new IP via Telnet port 1(Fig. 34)
Î Input telnet 10.0.50.101 1
Note:Telnet will fail and then SE5002 restarts automatically. Afterward, the new IP address is changed to

10.0.50.101

Step3: Using the new IP to configure SE5002 via Telnet
Î Input telnet 10.0.50.101
Note:
1. Both PC's IP and SE5002 's IP must belong to the same subnet.
2. The changed IP address must be legal; otherwise it will change back to the default value (10.0.50.100)

after restart.