Serialmanager auto ip dialog window, Configuration by telnet utility, Telnet to the system – Atop Technology SE5002 User manual User Manual
Page 13: System main menu, Fig. 8, 2 configuration, Telnet, Utility, Fig. 9, Fig. 10
User manual Version 1.3
ABLELink
®
Ethernet Serial Server SE5002
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
-
12
-
Fig. 8. SerialManager Auto IP Dialog Window
3.2 Configuration by Telnet utility:
One may also use Telnet utility to change configuration settings
.
Î Open Ms-DOS command prompt window
Î Enter in the “Telnet IP_address 23 ”.( For example, Telnet 10.0.50.100 23). The system then prompts
for a password, the default password is Null (Leave it blank). (Fig. 9)
Fig. 9. Telnet to the system
Note: One may press the reset button to reset the password..
1
Then the following main menu shall appear (Fig. 10)
Fig. 10. System main menu
Notes:
1. If the SE5002 does not receive any command within 1 minute, Telnet will be terminated automatically.
2. The changes of networking parameters will take effect only after the SE 5002 is exited and restarted.
->Select “1” from “Input choice and enter (0~5):” to enter “overview” .:(Fig. 11)