User manual Version 1.3

ABLELink

®

Ethernet Serial Server SE5002

Copyright © 2006 Atop Technologies, Inc.

All rights reserved. Designed in Taiwan.

-

12

-

Fig. 8. SerialManager Auto IP Dialog Window

3.2 Configuration by Telnet utility:

One may also use Telnet utility to change configuration settings

.

Î Open Ms-DOS command prompt window

Î Enter in the “Telnet IP_address 23 ”.( For example, Telnet 10.0.50.100 23). The system then prompts

for a password, the default password is Null (Leave it blank). (Fig. 9)

Fig. 9. Telnet to the system

Note: One may press the reset button to reset the password..
1

Then the following main menu shall appear (Fig. 10)

Fig. 10. System main menu

Notes:
1. If the SE5002 does not receive any command within 1 minute, Telnet will be terminated automatically.
2. The changes of networking parameters will take effect only after the SE 5002 is exited and restarted.

->Select “1” from “Input choice and enter (0~5):” to enter “overview” .:(Fig. 11)