3.3.4 Configuring SE5002 as TCP server
:
SE5002 is configured in a transparent mode by default (Fig. 26)
Î Click on “COM1” link and the following screen shall appear.
Î Configure SE5002 as TCP server
Î Input local listening port “4660”
1.To enable IP filter:
Î Check “IP filter”
Î Input source IP on “Source IP”
2.If not to enable IP filter:
Î Don’t check “IP filter”
Î Input idle time on “Please input idle time to send TCP keep-alive packet(sec):”( 2->the sending
TCP keep-alive packet period will be 2*10 sec)
Î Input TCP Inactivity time in “TCP Inactivity Time Before Disconnect( sec):”( 2->TCP Inactivity
beyond 2 sec will cause disconnect )
Î
Click on “Save Configuration” button to save the changes
Notes:
1.
One may configure COM1 or COM2 parameter by choosing COM1 or COM2 Link
2.
IP filtering function is disabled by setting FILTER_IP to “0.0.0.0”.
3.
IP filter is disabled by default
4.
If IP filter is enabled, only source IP assigned is connected to SE5002.