Link mode-tcp server setup, Fig. 15 – Atop Technology SE5002 User manual User Manual
Page 17
User manual Version 1.3
ABLELink
®
Ethernet Serial Server SE5002
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
-
16
-
Fig. 15. Link Mode-TCP server setup
Î Enter 2 on “Input choice(1~5) and enter:”(Fig. 15)
Î Input destination IP on “Please input Destination IP:” ( for instance: 10. 0. 29. 123)
Î Input destination port on “Please input Destination port:”( for instance: 666 )
1. Enter
1 for Connected always:
Î Double click “Enter” key
Î Input idle time in “Please input idle time to send TCP keep-alive packet(4*10sec):”( 2->the sending
TCP keep-alive packet period is 2*10 sec)
2. Enter
2 for Triggering by received COM port data:
Î Input idle time to disconnect on “Please input idle time to disconnect( 0sec , 1~255):” ( 0->disable
the function; 2 ->the serial Inactivity beyond 2 sec will cause disconnect)
Î Input error retrying time on “Please input waiting time for error retrying (0 minute,1~255):”
( 0->disable the function; 2 ->SE5002 trying to reconnect per 2 minutes)
Î Double click “Enter” key
Î Input idle time on “Please input idle time to send TCP keep-alive packet (4*10sec):”( 2-> sending
TCP keep-alive packet period will be 2*10 sec)