Fig. 2-5 attaching the Switch to a 19-inch rack


Desktop Installation


SNMP-FSH2602MG

has four rubber pads attached on each corner of its underside. These

pads serve as cushioning against vibration and prevent the switch from sliding off its
position. They also allow adequate ventilation space when you place the switch on top of
another device.

Fig. 2-6 Desktop installation

• The location you choose to install your switch and the way you configure your

network may greatly affect its performance. Please see the previous section for
“installation site” preparation.

• Do not place more than 3kg(6.6lbs) of weight on the top of the switch.

• Leave at least 10cm (4 inch) of space around the switch to allow proper heating

dissipation.


Cabling Requirements

For 100BASE-TX and 1000Base-T ports


The 24 RJ-45 station ports and 1000Base-T / Mini GBIC slot require Cat. 5 twisted-pair
UTP/STP cable for connection. When configuring within the 10/100/1000BASE-T cabling
architecture, the cable distance should be within 100m.