Online visualization – AiM MyChron3 XG Log User Manual
Page 70

Now, please follow the instructions listed here above:
• Check the box corresponding to the gearbox’s gear number;
• Engage the neutral gear;
• Press the “Continue” button;
• Engage the first gear;
• Press the “Continue” button;
• Repeat this procedure until the last gear has been engaged (the
instrument supports gearboxes up to 9 gears);
• Once the last gear has been engaged, press the “End Calibration” button;
• Once the gear calibration has finished, it is absolutely necessary to
transmit the calibration to your MyChron 3 Plus/Gold/Gold XG by
pressing the “Transmit calibration” button.
Online visualization
Once you finished calibrating/autocalibrating the sensors, it is suggested to enter
the “Online” mode, by pressing the Online button in the “Logger manager” main
window, in order to verify that each channel has been correctly configured.
The “Online” visualization mode will allow you to control if the
temperature/pressure sensors have been correctly set and if the gear sensor and
the accelerometers have been correctly calibrated. It is also possible to see the
“Battery charge level” and to start a test data acquisition, in order to verify that the
system is correctly working.
70