background image

Figure 8.17

2. Set the Emergency Stop switch € to on

(up) (see Figure 8.17).

3. Set the Ground/Platform Selector switch 

to platform (up) (see Figure 8.17).

4. Turn the key ‚ (see Figure 8.17) to on — do

not turn the key ‚ to start.

Figure 8.18

5. Enter the platform ƒ and close the gate „

(see Figure 8.18).

Figure 8.19

6. Turn the Emergency Stop switch …

clockwise and it will pop out (on) (see Figure
8.19).

7. If the engine is at ambient temperature,

momentarily press the GLOW-PLUG switch

†. This action will automatically turn the
glow-plugs, in the engine, on for 10 seconds.
A light ‡ will automatically come on to
indicate that the glow-plugs are on (see
Figure 8.19).

8. When the light ‡ goes out, press and hold

the START switch ~ until the engine starts
or for 20 seconds, whichever comes first.
When the engine starts, release the START
switch ~ (see Figure 8.19).

If the engine does not start in 20 seconds,
release the START switch (10) then wait 60
seconds before trying to start the engine
again with the GLOW-PLUG (8) and START
switches (10).

page 8 - 6

SR2770 – 11669A

8. Operation

CAUTION