Caution, Operation – Snorkel SR2770 User Manual
Page 49

Figure 8.17
2. Set the Emergency Stop switch to on
(up) (see Figure 8.17).
3. Set the Ground/Platform Selector switch
to platform (up) (see Figure 8.17).
4. Turn the key (see Figure 8.17) to on — do
not turn the key to start.
Figure 8.18
5. Enter the platform and close the gate
(see Figure 8.18).
Figure 8.19
6. Turn the Emergency Stop switch
clockwise and it will pop out (on) (see Figure
8.19).
7. If the engine is at ambient temperature,
momentarily press the GLOW-PLUG switch
. This action will automatically turn the
glow-plugs, in the engine, on for 10 seconds.
A light will automatically come on to
indicate that the glow-plugs are on (see
Figure 8.19).
8. When the light goes out, press and hold
the START switch ~ until the engine starts
or for 20 seconds, whichever comes first.
When the engine starts, release the START
switch ~ (see Figure 8.19).
If the engine does not start in 20 seconds,
release the START switch (10) then wait 60
seconds before trying to start the engine
again with the GLOW-PLUG (8) and START
switches (10).
page 8 - 6
SR2770 – 11669A
8. Operation
CAUTION