Example 1:

Pump Panel Lights

Assigned to PDM 3 Output 0

Pump Panel Switch

Assigned to PDM 3 Input 0

Marker Light Switch

Assigned to SIM 0 Input 0

The Pump Panel Lights are set to come on with the Pump Panel Switch or the Marker Light
Switch.

Multiplex

Logic

ON whenever the Pump Panel Switch is ON

OR

the Marker Light Switch is ON.

Management

Logic

defaults to true.

Vocation

Logic

defaults to true.

Whenever the Marker Light Switch or the Pump Panel Switch is turned on, the Pump
Panel Lights
will turn ON.

Example 2:

The Pump Panel Lights are set to come on with the Pump Panel Switch OR the Marker Light
Switch AND in Scene Mode.

Multiplex

Logic

ON whenever the Pump Panel Switch is ON

OR

the Marker Light Switch is ON.

AND

Management

Logic

set to mode B (Scene Mode).

AND

Vocation

Logic

defaults to true.

Whenever the Marker Light Switch or the Pump Panel Switch is turned on, the Pump
Panel Lights
will turn ON

as long as the Park Brake is set

.

Example 3:

The Pump Panel Lights are set to come on with the Pump Panel Switch OR the Marker Light
Switch AND in Scene Mode if it is Okay to Pump.

Multiplex

Logic

ON whenever the Pump Panel Switch is ON

OR

the Marker Light Switch is ON.

AND

Management

Logic

set to mode B (Scene Mode).

AND

Vocation

Logic

set to Okay to Pump.

Whenever the Marker Light Switch or the Pump Panel Switch is turned on, the Pump
Panel Lights
will turn ON

as long as the Park Brake is set

AND the pump is engaged and the

transmission is in high range lockup.

Example