POINT I/O Module and RSLogix 5000 Software Controller Tag Reference 127
1734-232ASC
1 Channel ASCII Interface Module
Configuration Data
Data Type
Default
Value
Valid Data Values
Serial Character Format
(ASCII Format:
Data Bits / Parity / Stop)
SINT
0
0=7N2
1=7E1
2=7O1
3=8N1
4=8N2
5=8E1
6=8O1
7=7E2
8=7O2
Serial Comm Speed
(Communication Rate of the Serial Port)
SINT
0
0=9600 Kbps
1=1200 Kbps
2=2400 Kbps
3=4800 Kbps
4=19.2 KBps
5=38.4 KBps
Max Receive Characters
SINT
20
-128…+127 (0…128)
Receive Start Delimiter Mode
SINT
0
0=No Start Delimiter
1=Exclude Start Delimiter
2=Include Start Delimiter
Receive Start Delimiter Character
SINT
58
(0x3A)
Any Valid ASCII Character
(Default is Colon [:])
Receive Record End Mode
SINT
2
0=No End Delimiter
1=Exclude End Delimiter
2=Include End Delimiter
Receive End Delimiter
SINT
13
(0x0d)
Any Valid ASCII Character
(Default is Carr. Return)
Receive String Data Type
SINT
1
0=Array
1=Short String
2=String
Pad Mode
SINT
1
0=Pad Mode Disabled
1=Pad Mode Enabled
Pad Character
SINT
0
(0x00)
Any Valid ASCII Character
(Default is NULL)
Receive Swap Mode
SINT
0
0=Disabled
1=16-bit Swap Enabled
2=24-bit Swap Enabled
3=32-bit Swap Enabled
DeviceNet Handshake Mode
SINT
1
0=Master/Slave handshake
1=Produce Immediate
Max Transmit Characters
SINT
20
-128…+127 (0…128)