beautypg.com

System software show commands, Common diagnostic scenarios, Draft: brocade confidential – Brocade 6910 Ethernet Access Switch Diagnostic Guide (Supporting R2.2.0.0) User Manual

Page 16

background image

6

Brocade 6910 Ethernet Access Switch Diagnostic Guide

53-1002653-01

2

DRAFT: BROCADE CONFIDENTIAL

Basic system information

System Temperature:

Unit 1

Temperature 1: 28 degrees Temperature 2: 26 degrees Temperature 3: 26 degrees

Main Power Status : Up

Redundant Power Status : Up

show alarm-status

Syntax: show alarm-status

This command displays information on predefined alarms (i.e., non-configurable) and on the
link-down alarm (which is displayed as a minor alarm).

Console# show alarm-status

Unit 1

Asserted Alarm Input : [NONE]

Current Major Alarm Status:

One of the power status is failed.

Current Minor Alarm Status:[NONE]

Current Major Alarm Output Status:[ACTIVE]

Current Minor Alarm Output Status:[INACTIVE]

System software show commands

show version

Syntax: show version

Most boot issues occur because incorrect or incompatible images have been downloaded. The
show version command displays all versions that are currently loaded, as shown in the following
example.

Console# show version

Unit 1

Serial Number : S123456

Hardware Version : R0A

EPLD Version : 0.00

Number of Ports : 12

Main Power Status : Up

Redundant Power Status : Up

Role : Master

Loader Version : 0.0.0.5

Linux Kernel Version : 2.6.22.18

Boot ROM Version : 0.0.0.1

Operation Code Version : 0.0.1.6

Common diagnostic scenarios

System issues are rare. However, some problem sources can include:

Software versions are not compatible.

Environmental conditions, such as temperatures that are above or below operating thresholds,
are affecting operation of hardware components.

If you are experiencing system issues, contact Brocade Technical Support for help in
troubleshooting your system.